Slewing Bearing for Demolition Robots | Impact Load Engineering Case | FDON

Application engineering study

When every impact reaches the rotary joint.

A compact demolition robot combines long reach with a high-frequency hydraulic breaker. The slewing bearing must carry the static moment, survive repeated shock and keep the gear-and-bolt interface stable.

COMPACT DEMOLITION ROBOTShock load path → boom → upper structure → slewing bearing → chassisSLEWING BEARINGHYDRAULIC BREAKER
Impact is not a single load value.The bearing sees a spectrum of axial, radial and overturning loads — plus bolt and gear-interface effects.
1.1 tMachine mass
3.7 mHorizontal reach
140 kgBreaker mass
254 JImpact energy
850–1,900Blows / minute

01 / Application context

Built for demolition.
Loaded through the boom.

The application is a compact remotely operated demolition robot working with a hydraulic breaker. Public demolition-robot platforms in this class are designed for restricted spaces, indoor demolition and interchangeable attachments. The rotary interface sits between a long-reach boom system and a tracked chassis, so the bearing sees repeated reversals and impact transmission rather than smooth continuous rotation.

For FDON, the selection question is not simply “Will the bearing rotate?” It is “What loads reach the raceway, gear teeth and mounting bolts while the breaker is striking?”

02 / First engineering check

Start with what can be calculated.
Then isolate what cannot.

01 / AXIAL REFERENCE

Machine self-weight

1,100 kg × 9.81 ≈ 10.8 kN. This is a conservative reference only; the actual axial load at the slewing bearing depends on machine architecture and support reactions.

02 / BREAKER WEIGHT

Attachment gravity load

140 kg × 9.81 ≈ 1.37 kN of static gravitational force from the breaker itself.

03 / STATIC MOMENT

Breaker at 3.7 m reach

1.37 kN × 3.7 m ≈ 5.1 kNm of static overturning moment from breaker weight alone.

Impact frequency14.2–31.7 Hz
Nominal impact energy254 J / blow
Average impact power≈ 3.6–8.0 kW
254 J × (850–1,900) / 60 ≈ 3.6–8.0 kW

Why this still does not give the peak bearing load

Impact energy in joules and blows per minute describe the breaker, but they do not directly define the peak Fa, Fr or Mk acting at the slewing axis. The transmitted peak force depends on contact stiffness, boom geometry, hydraulic dynamics, damping and structural flexibility.

Engineering boundary: do not convert 254 J directly into a “bearing force” without a defined impact displacement or measured reaction load.

03 / Shock & vibration review

Static capacity is only
the first gate.

For a demolition robot, the rotary joint should be reviewed as a complete load path. Raceway capacity, bolt joint, supporting structure and gear mesh all respond to the same repeated impact.

01

Dynamic load spectrum

Confirm maximum axial load, radial load and overturning moment during actual breaker operation, including worst boom position.

02

Mounting bolts

Use the specified bolt grade and controlled preload. Repeated vibration makes preload retention and joint stiffness critical.

03

Mounting flatness

Uneven support faces distort the rings, alter clearance and can create localized raceway loading under impact.

04

Gear mesh & backlash

Check backlash around the full rotation, especially at the ring-gear runout high point. Shock can magnify tooth-edge contact.

05

Clearance & friction

Small clearance improves stiffness, but too little clearance after mounting deformation can increase torque and heat.

06

Lubrication & sealing

Demolition dust and vibration demand robust sealing, suitable grease and realistic relubrication intervals.

04 / Bearing interface

A compact four-point ring
can be a practical starting point.

A single-row four-point contact slewing bearing can support combined axial, radial and overturning loads in a compact envelope. For this application, the final choice should be checked against the actual static limiting-load curve and the dynamic shock case, not only the outside diameter.

Explore FDON four-point contact slewing bearings ↗

Technical support center ↗

Design itemWhy it matters on a demolition robot
Raceway capacityPlot the factored Fa/Mk operating point on the bearing load curve.
Gear hardeningRepeated impact and reversing torque increase tooth-contact stress and wear sensitivity.
Axial / radial clearanceMust remain within the agreed range after mounting and structural distortion.
Bolt circle & gradeThe bolt joint may become the limiting condition before the raceway in high-moment service.
Support stiffnessThin or uneven mounting structures can invalidate a bearing-only capacity check.
InspectionRunout, hardness, clearance and gear checks should be tied to the approved drawing.

05 / Engineering conclusion

What we can say now — and what still needs data.

Supported by the current data

The breaker’s static gravity moment is approximately 5.1 kNm. The machine mass corresponds to approximately 10.8 kN of gravitational force. These values provide a first static reference and can be compared with the candidate bearing’s limiting-load curve.

Required before final approval

Provide the maximum Fa, Fr and Mk during hammering. If those are not available, provide boom/arm weights, centers of gravity, maximum breaker reaction force, worst working position, duty cycle and mounting-structure details.

This page is an application engineering study, not a claim of machine-level certification. The machine builder remains responsible for validating the complete structure and operating duty.

06 / Engineer FAQ

Questions that matter
before production.

These are the items that determine whether a promising static check becomes a robust demolition-robot rotary joint.

Can 254 J be converted directly into a peak force on the bearing?

No. You need either the measured / calculated joint reaction loads or a defined deformation and structural model. Impact energy alone is insufficient.

Is the 140 kg breaker weight the only source of overturning moment?

No. Boom and arm masses, their centers of gravity, acceleration, breakout forces and breaker reaction all contribute to the load at the slewing axis.

Why check bolts separately from the raceway?

The bearing raceway and mounting-bolt joint have different limiting conditions. In some low-axial / high-moment cases, the bolt curve can govern first.

What should be included in the final drawing review?

Mounting dimensions, hole pattern, gear data, material and heat treatment, clearance, runout, bolt grade and preload, sealing, lubrication, and the required inspection report.

07 / Review your demolition robot

Send the rotary-joint data.
We will start with the load path.

For a new design or a replacement, send the bearing / assembly drawing and the machine load case. We can review the slewing bearing, gear interface and the information still needed for a reliable quotation.

Email Steven ↗

Minimum engineering brief

Machine
Operating mass, maximum reach, working positions
Attachment
Breaker mass, impact energy, blows/min, max reaction force if available
Loads
Maximum Fa, Fr and Mk at the slewing axis
Motion
Rotation angle, speed, reversing duty, cycle frequency
Interface
OD / ID / height, bolt circles, gear data, mounting-face thickness
Environment
Dust, temperature, water exposure, lubrication interval